FixVault

Function Test (1.8L)

Disconnect actuator cable from accelerator. Start engine to supply vacuum to actuator diaphragm. Apply battery voltage and ground to specified terminals of actuator and observe actuator arm. See the ACTUATOR FUNCTION TEST  . SeeFigure . If actuator arm does not function as specified, replace actuator.

ACTUATOR FUNCTION TEST (1.8L)

Apply Voltage to Terminals: Actuator Arm Result
Apply 12 Volts To "A" & Ground "B", "C" & "D" Pull
Apply 12 Volts To "A" & Ground "B" & "C" Hold
Apply 12 Volts To "A" & Ground "B" Extend
Disconnect All Voltage & Ground Release