Intake Air Temperature (IAT) Sensor: MPV

Locate and remove IAT sensor from dynamic chamber. Place IAT sensor and thermometer in a container of water. Connect ohmmeter between IAT sensor terminals. Slowly heat water. Observe resistance at specified temperatures. See INTAKE AIR TEMPERATURE SENSOR SPECIFICATIONS (MILLENIA 2.5L, MPV, PROTEGE 1.5L & 626) table. If resistance is not as specified, replace IAT sensor.

INTAKE AIR TEMPERATURE SENSOR SPECIFICATIONS (MILLENIA 2.5L, MPV, PROTEGE 1.5L & 626)

Temperature °F (°C) Ohms
Millenia 2.5L
68 (20) 2200-2700
176 (80) 290-350
MPV
77 (25) 30,000-36,000
185 (85) 3300-3700
626
68 (20) 35,500-39,200
140 (60) 7180-7920
Protege 1.5L
68 (20) 2200-2700
176 (80) 290-340