FixVault

Purge Control Solenoid Valve

Disconnect purge control solenoid valve connector. See PURGE CONTROL SOLENOID VALVE LOCATIONS  table. Ensure air does not flow through solenoid valve vacuum ports. Using jumper wires, apply battery voltage to solenoid valve terminals. Apply air pressure to a solenoid valve port. Air should flow from other port. If valve does not operate as specified, replace solenoid valve.

PURGE CONTROL SOLENOID VALVE LOCATIONS

Application Location
Miata Right Front Of Engine Compartment
Millenia
2.3L Top Right Of Engine
2.5L Center Rear Of Engine Compartment
626
2.0L On Right Side Of Plenum
2.5L Between Air Filter & Battery
Protege Center Rear Of Engine Compartment