Purge Control Solenoid Valve
Disconnect purge control solenoid valve connector. See PURGE CONTROL SOLENOID VALVE LOCATIONS table. Ensure air does not flow through solenoid valve vacuum ports. Using jumper wires, apply battery voltage to solenoid valve terminals. Apply air pressure to a solenoid valve port. Air should flow from other port. If valve does not operate as specified, replace solenoid valve.
PURGE CONTROL SOLENOID VALVE LOCATIONS
| Application | Location | |
|---|---|---|
| Miata | Right Front Of Engine Compartment | |
| Millenia | ||
| 2.3L | Top Right Of Engine | |
| 2.5L | Center Rear Of Engine Compartment | |
| 626 | ||
| 2.0L | On Right Side Of Plenum | |
| 2.5L | Between Air Filter & Battery | |
| Protege | Center Rear Of Engine Compartment | |