"Ten" Terminal On 17-Pin Diagnostic Connector (5810)
Publication date: 2009-01-01Reference number: 5810
"TEN" TERMINAL ON 17-PIN DIAGNOSTIC CONNECTOR
TECHNICAL SERVICE BULLETIN
Reference Number(s): 5810
| MAZDA: | 1997-2002 Millenia; 1997-2006 MPV |
| SECTION: | MTOL |
APPLICABLE MODELS
APPLICABLE MODELS
| Model | Starting S/N | Ending S/N | Model Spec |
|---|---|---|---|
| Millenia 1997-2002 | 000000 | ZZZZZZ | |
| MPV 1997-1998 | 000000 | ZZZZZZ | |
| MPV 1997-1998 | 000000 | ZZZZZZ |
RELATED CATEGORY/SUBCATEGORY/SYMPTOMS
Brakes / Conventional Brake System / Does Not Turn-Off/Warning Light
Engine / Fuel System / Serviceability
Engine / On-Board Diagnostics / Does Not Turn-On/Warning Light
HVAC / Basic System / Improper Operation
MTOL - 5810 DEALER REPAIR INFORMATION
Symptom and Conditions
Some PCMs on some models cannot detect grounding of its TEN terminal when "GROUND" is selected after selecting "Test" on a list of PIDs in PCM Datalogger. As a result, feedback controls for ignition timing, IAC, and fuel trim are not terminated and engine adjustments cannot be made using M-MDS.
Repair Procedure
Follow the instructions on screen when displayed state for the PID "Test" does not turn to "ON" in PCM datalogger.