FixVault

Power Window Main Switch Inspection

  1. Inspect for continuity between the terminals of the power window main switch connector with the main switch in the following positions.
  2. When inspecting the driver's side, connect the B+ to terminal H and connect the GND to the terminal F.
    • If not as specified, replace the power window main switch.
    Fig 1: Inspecting Continuity In Power Window Main Switch
    G00382199Courtesy of MAZDA MOTORS CORP.
    Fig 2: Inspecting Power Window Switch Connectors
    G00382200Courtesy of MAZDA MOTORS CORP.