FixVault

Detection Condition

PCM monitors input signal from Knock Sensor (KS) when monitoring conditions are met.

Monitoring Conditions

If PCM does not receive input signal from KS for 5 seconds, PCM determines that KS circuit is malfunctioning. This is a Continuous Monitor (CM). MIL illuminates if PCM detects malfunction condition during first drive cycle. Pending code is not available. Freeze Frame Data is available and DTC is stored in PCM memory.