FixVault

Airflow Mode Wire

  1. Set the airflow mode control dial at VENT.
  2. Set the airflow mode link to VENT in the direction shown by the arrow and insert a screwdriver at the set hole.
    Fig 1: Verifying Airflow Mode Control Dial
    G00992181Courtesy of MAZDA MOTORS CORP.
  3. Connect the airflow mode wire to airflow mode link.
  4. Clamp the airflow mode wire to wire clamp.
  5. Verify that the airflow mode control dial moves its full stroke.