Metering Oil Pump Switch Inspection
›
Circuit Open/Short Inspection
›
Short circuit
Short circuit
If there is continuity in the following wiring harnesses, there is a short circuit. Repair or replace the wiring harness.
Metering oil pump switch terminal A and body ground
Metering oil pump switch terminal A and power supply