Inspection Using An Oscilloscope (Reference)
›
Field coil control (Generator)
Field coil control (Generator)
Terminal connected: 21 (+)-Negative battery terminal
Oscilloscope setting: 0.5 V/DIV (Y): 1 ms/DIV (X), DC range
Measurement condition: Idling after warm-up (no load)
Fig 1: Identifying Field Coil Control (Generator) Graph
Courtesy of MAZDA MOTORS CORP.