FixVault

Check code 22

CHECK CODE 22

Check code 22 Fuel level signal
STEP INSPECTION CONDITION DISPLAY ACTION
1 Select check code 22 with the fuel gauge sender unit connector disconnected. 252 - 255 Go to the next step.
Except above Replace the instrument cluster.
2 Connect terminals 2U and 2W of the instrument cluster. 000-003 Go to the next step.
Except above Replace the instrument cluster.
3 Using the SST  (Fuel and thermometer checker) or resistor, input 20 ohms  between instrument cluster terminals 2U and 2W. 017-023 Go to the next step.
Except above Replace the instrument cluster.
4 Using the SST  (Fuel and thermometer checker) or resistor, input 100 ohms  between instrument cluster terminals 2U and 2W. 097-103 Go to the next step.
Except above Replace the instrument cluster.
5 Using the SST  (Fuel and thermometer checker) or resistor, input 200 ohms  between instrument cluster terminals 2U and 2W. 197-203 Inspect the fuel gauge sender unit.
Except above Replace the instrument cluster.