FixVault

Diagnostic procedure

CHECK CODE 18 DIAGNOSTIC PROCEDURE

INSPECTION INDICATION SITUATION ACTION
Wait for 2 seconds after selecting check code 18. on
(Turns on and off)
Ignition key illumination turns on and off three times  . Ignition key illumination is okay.
Other than stated above. Measure voltage at instrument cluster terminal 2C.
Is voltage B+  ?
  • If as specified, replace instrument cluster.
  • If not as specified, inspect following parts.
    • Ignition key illumination
    • Wiring harness (Battery-ignition key illumination-instrument cluster)