Diagnostic procedure
DTC P2127 [L3] DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |||||
|---|---|---|---|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. | ||||
| No | Record FREEZE FRAME DATA on repair order, then go to the next step. | ||||||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
||||
| No | Go to the next step. | ||||||
| 3 | CLASSIFY APP SENSOR OR HARNESS MALFUNCTION
|
Yes | Go to the next step. | ||||
| No | Go to step 5. | ||||||
| 4 | INSPECT APP SENSOR
|
Yes | Inspect for poor APP sensor connector terminal A connection. Repair or replace if necessary, then go to Step 8. | ||||
| No | Replace APP sensor, then go to Step 8. | ||||||
| 5 | INSPECT POWER SUPPLY CIRCUIT VOLTAGE AT APP SENSOR CONNECTOR
|
Yes | Go to the next step. | ||||
| No | Repair or replace open circuit between APP sensor connector terminal A and PCM connector terminal 8(1), 2K(2) (harness-side). Then, then go to Step 8. |
||||||
| 6 | VERIFY APP2 SIGNAL CIRCUIT FOR OPEN CIRCUIT |
Yes | Go to the next step. | ||||
| No | Repair or replace suspected harness, then go to Step 8. | ||||||
| 7 | VERIFY APP2 SIGNAL CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace suspected harness, then go to the next step. | ||||
| No | Go to the next step. | ||||||
| 8 | VERIFY TROUBLESHOOTING OF DTC P2127 COMPLETED
|
Yes | Replace PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION .) |
||||
| No | Go to the next step. | ||||||
| 9 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
||||
| No | Troubleshooting completed. | ||||||
|
|||||||