Diagnostic procedure
DTC P2128 [L3] DIAGNOSTIC PROCEDURE
| STEP | INSPECTION | ACTION | |||||
|---|---|---|---|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. | ||||
| No | Record FREEZE FRAME DATA on repair order, then go to the next step. | ||||||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
||||
| No | Go to the next step. | ||||||
| 3 | INSPECT APP SENSOR CONNECTOR
|
Yes | Go to the next step. | ||||
| No | Connect the connector securely, then go to Step 10. | ||||||
| 4 | INSPECT APP SENSOR CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace suspected terminal, then go to Step 10. | ||||
| No | Go to the next step. | ||||||
| 5 | INSPECT APP SENSOR
|
Yes | Go to the next step. | ||||
| No | Replace APP sensor, then go to Step 10. | ||||||
| 6 | INSPECT APP2 SIGNAL CIRCUIT FOR SHORT TO POWER SUPPLY |
Yes | Repair or replace short to power supply. Then, go to Step 10. | ||||
| No | Go to the next step. | ||||||
| 7 | VERIFY APP SENSOR GROUND CIRCUIT FOR OPEN CIRCUIT |
Yes | Repair or replace open circuit between APP sensor terminal C (harness-side) and PCM connector terminal 42(1), 2A(2) (harness-side). Then, go to Step 10. | ||||
| No | Go to the next step. | ||||||
| 8 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair terminal, then go to Step 10. | ||||
| No | Go to the next step. | ||||||
| 9 | VERIFY APP SIGNAL CIRCUIT FOR SHORT TO CONSTANT VOLTAGE CIRCUIT
|
Yes | Repair or replace suspected harness, then go to the next step. | ||||
| No | Go to the next step. | ||||||
| 10 | VERIFY TROUBLESHOOTING OF DTC P2128 COMPLETED
|
Yes | Replace PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION .) |
||||
| No | Go to the next step. | ||||||
| 11 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE .) |
||||
| No | Troubleshooting completed. | ||||||
|
|||||||