FixVault

Door Key Cylinder Switch Inspection

  1. Disconnect the door key cylinder switch connector.
  2. Inspect for continuity between the door key cylinder switch terminals using an ohmmeter.
    • If not as specified, replace the door key cylinder switch.
    Fig 1: Key Cylinder Position And Terminals Continuity Chart
    G03701213Courtesy of MAZDA MOTORS CORP.
    Fig 2: Inspecting Door Key Cylinder Switch Continuity
    G03701214Courtesy of MAZDA MOTORS CORP.