FixVault

Liftgate Lock Actuator Inspection

  1. Disconnect the liftgate lock actuator connector.
  2. Apply battery positive voltage to the liftgate lock actuator terminals and inspect the operation of the liftgate lock actuator.
    • If not as specified, replace the liftgate lock.
    TERMINALS CONNECTION AND LIFTGATE LOCK ACTUATOR DESCRIPTION

    Connection Actuator operation
    B+ GND
    B A Lock
    A B Unlock
    Fig 1: Inspecting Liftgate Lock Actuator Operation
    G03701211Courtesy of MAZDA MOTORS CORP.