Liftgate Lock Cylinder Switch Inspection

  1. Disconnect the liftgate lock cylinder switch connector.
  2. Inspect for continuity between the liftgate lock cylinder switch terminals using an ohmmeter.
    • If not as specified, replace the liftgate lock cylinder switch.
    Fig 1: Lock Cylinder Position And Terminals Continuity Chart
    G03701216Courtesy of MAZDA MOTORS CORP.
    Fig 2: Inspecting Liftgate Lock Cylinder Switch Continuity
    G03701217Courtesy of MAZDA MOTORS CORP.