Evaporative Emission System Leak Test
CAUTION:
- The evaporative emission system must not be pressurized to more than 3.48 kPa (14 inches H2 O) or damage to the evaporative emission system may occur.
- Connect the Evaporative Emission System Leak Tester to the evaporative emission test port.
- Close the canister vent solenoid. See CANISTER VENT SOLENOID CLOSING PROCEDURE .
- Pressurize the evaporative emission system to 3.48 kPa (14 inches H2 O).
- Monitor the system for two minutes. The system fails the leak test if the pressure falls below 2.0 kPa (8 inches H2 O).
- Repair any leaks as necessary.
- Repeat the leak test until the system remains above 2.0 kPa (8 inches H2 O)) after the two-minute test period.