FixVault

Fuel Pump Operation Inspection

CAUTION:
  • Connecting the wrong check connector terminal may possibly cause malfunction. Carefully connect the specified terminal only.
  1. Short the check connector terminal F/P to body GND using a jumper wire. (See AFTER REPAIR PROCEDURE .)
  2. Remove the fuel-filler cap.
  3. Turn ignition switch to ON position.
  4. Verify that the fuel pump operation sound is heard.
    • If no operation sound is heard, proceed to next step.
  5. Measure the voltage at harness side fuel pump connector terminal B.

Specification 

B+ (Ignition switch at ON)