FixVault
Home
›
Mazda
›
2006
›
MPV LX
›
Repair and Diagnosis
›
Engine Performance
›
Engine Control Systems
›
Pcm Inspection
›
Inspection Using An Oscilloscope (Reference) CKP
›
Generator field coil signal
Generator field coil signal
PCM terminal: 36 (+)-100 (-)
Oscilloscope setting: 0.5V/DIV (Y), 1ms/DIV (X), DC range
Vehicle condition: idle after warm up
Fig 1: Identifying Generator Field Coil Signal Waveform
Courtesy of MAZDA MOTORS CORP.