FixVault

Air Gap Inspection

  1. Verify that the CKP sensor is securely installed.
  2. Using a thickness gauge, measure the air gap between the plate projections at the back of crankshaft pulley and the CKP sensor.
    • If not within the specification, inspect the plate projections for cracks or bending.
      Fig 1: Identifying Air Gap Between Plate Projections At Back Of Crankshaft Pulley & CKP Sensor
      G04323032Courtesy of MAZDA MOTORS CORP.

      Air gap 

      0.5-1.5 mm {0.02-0.05 in}