FixVault

DTC P2407: Notes

DTC P2407 (LF, L3) DETECTION CONDITION AND POSSIBLE CAUSES

DTC P2407 EVAP system leak detection pump sense circuit intermittent
DETECTION CONDITION 
  • The PCM monitors pump load current (EVAP line pressure), while evaporative leak monitor is operating. When either of the following is detected 6 times or more successively, the PCM determines EVAP system leak detection pump heater has a malfunction:
    • While obtaining the reference current value, the change in pump load current exceeds the specification.
    • After obtaining the reference current value, the pump load current is kept lower than the maximum pump load current for more than the specified time.

Diagnostic support note 
  • This is a intermittent monitor (CCM).
  • The MIL illuminates if PCM detects the above malfunction condition in two consecutive drive cycles or in one drive cycle while DTC for the malfunction has been stored in PCM.
  • PENDING CODE is available if PCM detects the above malfunction condition.
  • FREEZE FRAME DATA is available.
  • DTC is stored in PCM memory.
POSSIBLE CAUSE 
  • EVAP system leak detection pump heater malfunction
  • PCM malfunction