FixVault

Front HO2S Heater Resistance Inspection

  1. Disconnect the front HO2S connector.
  2. Measure the resistance between front HO2S terminals 2B and 2D.

    Front HO2S heater resistance 

    1-10 ohms 

    Fig 1: Identifying Front HO2S Connector Terminals
    G04325271Courtesy of MAZDA MOTORS CORP.