FixVault

Main Relay Operation Inspection

  1. Verify that the main relay clicks when the ignition switch is turned to ON position and then off.
    • If there is no operation sound, inspect the following:
      • Main relay (See RELAY INSPECTION ).
      • Wiring harness and connector between ignition switch and main relay terminal A.
      • Wiring harness and connector between PCM terminal 2X and main relay terminal E.