No.2 Additional Key Registration Procedure (Using the M-MDS): Procedure
- Have one key (key 1) ready for registration.
- Connect the M-MDS to the DLC-2. (See
M-MDS Connecting Procedure .)
- Using key 1, turn the ignition switch to the ON position.
NOTE:
- Although the security light starts flashing and DTC 15 is displayed after approx. 1 min, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
- After the vehicle is identified, select the following items from the initial screen of the M-MDS.
- When using the IDS (laptop PC)
- Select the "Toolbox" tab.
- Select "Body".
- Select "Security".
- When using the PDS (Pocket PC)
- Then, select items from the screen menu in the following order.
- Select "PATS Functions".
- Select "Program additional ignition key" from the M-MDS screen menu and perform the procedure according to the M-MDS screen
- Perform the security access according to the directions on the M-MDS screen. (See
SECURITY ACCESS PROCEDURE .)
NOTE:
- After selecting the above menu, "This operation has been successful" is displayed. At this point, the key that turned the ignition switch to the ON position is completely programmed.
- In this procedure, the necessary number of the keys are completely programmed. To finish the additional key programming, go to 11.
- If additional keys need to be programmed, go to the next step.
- After verifying that the PATS function menu is displayed again on the M-MDS screen, turn the ignition switch to the LOCK position and remove key 1.
- Using the additional key to be programmed, turn the ignition switch to the ON position.
- Return to the Step 3.
- After verifying that the PATS function menu is displayed again on the M-MDS screen, select the "Exit (From This Menu)" to finish the M-MDS procedure.
- After Step 11, wait 5 s or more
and then turn the ignition switch to the LOCK position.
- Disconnect the M-MDS from the DLC-2.
- Verify that the all keys can start the engine for 5 s or more
after the procedure.