FixVault

No.3 Key Replacement Procedure (Clearing Previously Registered Key ID Numbers, Key Re-registration): Procedure

Fig 1: Identifying Key For Registration
G04928950Courtesy of MAZDA MOTORS CORP.
  1. Have two or more keys (key 1, key 2) ready for registration after the clearing the key ID numbers.
  2. Using key 1, turn the ignition switch to the ON position.
    NOTE:
    • Although the security light flashes and DTC 15 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
  3. Connect the M-MDS to the DLC-2.
  4. Select "Body/Security/PATS function" from the screen menu of the M-MDS.
  5. Perform security access as indicated on the M-MDS screen. (see No.6 Security Access Procedure  .)
  6. Select "Ignition key ID number Erase" from the screen menu of the M-MDS and perform the tasks according to the M-MDS screen.
  7. After verifying that the PATS function menu is displayed again on the M-MDS screen, select "Exit" to complete the M-MDS function.
  8. After Step 7, wait 10 s or more  and turn the ignition switch to the LOCK position using key 1.
  9. Using key 1, turn the ignition switch to the ON position.
  10. After verifying that the security light illuminates for 3 s or more  , turn the ignition switch to the LOCK position and remove key 1.
    NOTE:
    • Although the security light flashes and DTC 21 is displayed, this does not indicate an improper procedure. Continue to perform the procedure as indicated.
  11. Using key 2, turn the ignition switch to the ON position.
  12. Verify that the security light illuminates for approx. 3 s  and then goes out.
  13. After verifying that the security light goes out, turn the ignition switch to the LOCK position using key 2, and then remove key 2.
  14. If additional keys need to be registered, repeat Steps 1113 in the same manner as key 2. Steps 1113 must be performed within 1 min  for each key. If the ignition switch is maintained in the ON position for 1 min  or more, key registration according to Steps 1113 will not be possible. If this occurs, refer to "09-14-50 NO.1 ADDITIONAL KEY REGISTRATION PROCEDURE  (Using Two Valid Keys)" to register any additional keys.