Diagnostic procedure
DTC P1686 DIAGNOSTIC PROCEDURE CHART
| STEP | INSPECTION | ACTION | |
|---|---|---|---|
| 1 | VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
|
Yes | Go to the next step. |
| No | Record the FREEZE FRAME DATA on the repair order, then go to the next step. | ||
| 2 | VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 3 | INSPECT METERING OIL PUMP CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to Step 13. |
| No | Go to the next step. | ||
| 4 | INSPECT METERING OIL PUMP POWER CIRCUIT FOR OPEN CIRCUIT OR SHORT TO GROUND
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit or short to ground, then go to Step 13. | ||
| 5 | INSPECT METERING OIL PUMP CONTROL CIRCUIT FOR SHORT TO GROUND
|
Yes | Repair or replace the wiring harness for a possible short to ground, then go to Step 13. |
| No | Go to the next step. | ||
| 6 | INSPECT METERING OIL PUMP
|
Yes | Replace the metering oil pump, then go to Step 13. (See METERING OIL PUMP REMOVAL/INSTALLATION ) |
| No | Go to the next step. | ||
| 7 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to Step 13. |
| No | Go to the next step. | ||
| 8 | INSPECT METERING OIL PUMP CONTROL CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to Step 13. | ||
| 9 | INSPECT METERING OIL PUMP SWITCH CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to Step 13. |
| No | Go to the next step. | ||
| 10 | INSPECT METERING OIL PUMP SWITCH
|
Yes | Replace the metering oil pump, then go to Step 13. (See METERING OIL PUMP REMOVAL/INSTALLATION ) |
| No | Go to the next step. | ||
| 11 | INSPECT PCM CONNECTOR FOR POOR CONNECTION
|
Yes | Repair or replace the terminal, then go to Step 13. |
| No | Go to the next step. | ||
| 12 | INSPECT METERING OIL PUMP SWITCH SIGNAL CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then go to the next step. | ||
| 13 | VERIFY TROUBLESHOOTING OF DTC P1686 COMPLETED
|
Yes | Replace the PCM, then go to the next step. (See PCM REMOVAL/INSTALLATION ) |
| No | Go to the next step. | ||
| 14 | VERIFY AFTER REPAIR PROCEDURE
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE ). |
| No | DTC troubleshooting completed. | ||