FixVault

ECT Sensor Resistance Inspection

  1. Drain the engine coolant. (See COOLING SYSTEM SERVICE WARNINGS [L3 WITH TC] .)
  2. Remove the ECT sensor (located above the starter).
  3. Place the ECT sensor in water with a thermometer, and heat the water gradually.
  4. Measure the resistance between the ECT sensor terminals A and B using a tester.
    • If not as specified, replace the ECT sensor.
    • If the ECT sensor is normal, but PID value is out of specification, perform the "CIRCUIT OPEN/SHORT INSPECTION ".
    WATER TEMPERATURE AND RESISTANCE SPECIFICATION

    Water temperature (°C {°F}) Resistance (kilohm)
    20 {68} 35.48-39.20
    80 {176} 3.65-4.02