FixVault

NO. 1 Additional Key Programming Procedure (Using Two Valid Keys): Procedure

Step Procedure Action after procedure
1 START ENGINE 
  1. Start the engine using key 1.
  2. Verify that the security light illuminates for approx. 3 s  and then turns off.
  3. Turn the ignition switch to the LOCK position.
Go to the next step.
2 LAUNCH PROGRAMMING MODE 
  1. Turn the ignition switch to the ON position using key 1.
  2. After verifying that the security light illuminates for approx. 3 s  and turns off, turn the ignition switch to the LOCK position within approx. 4 s  using key 1.
  3. Remove key 1.
  4. Turn the ignition switch to the ON position using key 2.
  5. After verifying that the security light illuminates for approx. 3 s  and turns off, turn the ignition switch to the LOCK position within approx. 4 s  using key 2.
  6. Remove key 2.
Go to next step.
3 PERFORM ADDITIONAL KEY PROGRAMMING 
  1. Turn the ignition switch to the ON position using key 3.
  2. Verify that the security light illuminates for approx. 3 s  and turns off.
  3. Remove key 3.
  4. Are there other keys to be programmed?
Yes Go back to Step 2.
No Go to the next step.
4 VERIFY KEY PROGRAMMING IS CORRECT 
Verify that the engine can start and run for approx. 5 s or more using all the programmed keys.
NOTE: When verifying that the engine starts, wait at least approx. 5 s or more  before starting the engine using the next key.
Procedure is completed