DTC Description Action
U0073:00 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0101:00 Communication error to TCM (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0121:00 Communication error to DSC HU/CM
U0155:00 Communication error to instrument cluster
U0073 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0100 Communication error to PCM (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0121 Communication error to DSC HU/CM
U0401 Abnormal message from PCM (See DTC U0401:00 [FS5A-EL] .)
U0415 Abnormal message from DSC HU/CM (See DTC U0415:00 [FS5A-EL] .)
U0073 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0100 Communication error to PCM (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0101 Communication error to TCM
U0140 Communication error to BCM
U1900 Communication error to other module (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U2023 Abnormal message from PCM (See DTC U2023 .)
U0073 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0155 Communication error to instrument cluster (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0073 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0100 Communication error to PCM (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0101 Communication error to TCM
U0401 Abnormal message from PCM (See DTC U0401 [BCM] .)
U0073 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0100 Communication error to PCM (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0140 Communication error to BCM
U0323 Communication error to instrument cluster
U2023 Abnormal message from PCM (See DTC U2023 [ADVANCED KEYLESS ENTRY AND START SYSTEM] .)
U0001:88 CAN system communication error (See DTC U0001:88, U0073, U0073:00, U1900 [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0100:00 Communication error to PCM (See DETERMINING MALFUNCTIONING PART (HS-CAN) [MULTIPLEX COMMUNICATION SYSTEM (L5)] .)
U0100:87 Communication error to PCM (no response)
U0101:00 Communication error to TCM
U0121:00 Communication error to DSC HU/CM
U0140:00 Communication error to BCM
U0151:00 Communication error to SAS control module
U0214:00 Communication error to keyless control module
U0401:68 Signal error from PCM (See DTC U0401:68 [INSTRUMENT CLUSTER] .)
U0401:92 Signal error from PCM (See DTC U0401:92 [INSTRUMENT CLUSTER] .)
U0402:68 Signal error from TCM (See DTC U0402:68 [INSTRUMENT CLUSTER] .)
U0402:92 Signal error from TCM (See DTC U0402:92 [INSTRUMENT CLUSTER] .)
U0415:68 Signal error from DSC HU/CM (See DTC U0415:68 [INSTRUMENT CLUSTER] .)
U0415:92 Signal error from DSC HU/CM (See DTC U0415:92 [INSTRUMENT CLUSTER] .)
U0452:92 Signal error from SAS control module (See DTC U0452:92 [INSTRUMENT CLUSTER] .)
U0515:68 Signal error from keyless control module (See DTC U0515:68 [INSTRUMENT CLUSTER] .)
U0515:92 Signal error from keyless control module (See DTC U0515:92 [INSTRUMENT CLUSTER] .)
U2005:86 Signal error from PCM (See DTC U2005:86 [INSTRUMENT CLUSTER] .)