FixVault

ECT Sensor No.2 Inspection

  1. Disconnect the negative battery cable.
  2. Drain the engine coolant. (See COOLING SYSTEM SERVICE WARNINGS .)
  3. Disconnect the ECT sensor No.2 connector.
  4. Remove the ECT sensor No.2. (See PCM CONFIGURATION .)
  5. Place the ECT sensor No.2 in water with a thermometer, and heat the water gradually.
  6. Measure the resistance between the ECT sensor No.2 terminals using an ohmmeter.
    Fig 1: Identifying ECT Sensor No.2 Connector Terminals
    G08107420
ECT SENSOR NO.2 SPECIFICATION

ECT (°C {°F}) Resistance (kilohms)
20{68} Approx. 2.45
80{176} Approx. 0.318