DTC B113E:11 [Advanced Keyless Entry And Push Button Start System]: Notes

DETECTION CONDITION  Trunk lid opener switch (vehicle exterior) circuit voltage less than 1 V  is detected for 1 s  , while ignition switch is ON
POSSIBLE CAUSE 
  • Connector or terminal malfunction
  • Trunk lid opener switch (vehicle exterior) malfunction
  • Short to ground in wiring harness between trunk lid opener switch (vehicle exterior) terminal B (vehicles with rear mount camera), F (vehicles without rear mount camera) and keyless control module terminal 3G
  • Short to ground in wiring harness between trunk lid opener switch (vehicle exterior) terminal B (vehicles with rear mount camera), F (vehicles without rear mount camera) and BCM terminal 6E
  • BCM malfunction
  • Keyless control module malfunction
G08143928