FixVault

For Left Bank

  1. Disconnect OCV (LH) connector.
  2. Warm up the engine to idle.
  3. Apply the battery voltage to the OCV and verify that the engine idles roughly or stalls.
    • If the engine idles roughly or stalls, inspect the timing belt component (valve timing deviation).
    • If the engine does not idle roughly or stall, go to the next step.
  4. Remove the OCV (LH) and perform spool valve operation inspection. (See OIL CONTROL VALVE (OCV) REMOVAL/INSTALLATION .)
    • If not as specified, inspect the following:
    • If as specified, inspect the following left bank hydraulic passages for clogging or leakage or both.
      • Oil pressure switch- OCV
      • OCV-Camshaft
      • Camshaft internal passage
  5. If they are normal, replace the left bank camshaft pulley (with built-in variable valve timing actuator).