FixVault

DTC P0011-00: Intake CMP Timing Over-Advanced: Notes

DETECTION CONDITION AND POSSIBLE CAUSE

DTC P0011:00 Intake CMP timing over-advanced
DETECTION CONDITION 
  • The actual intake valve timing advance is the specification or more compared to the target intake valve timing for a continuous specified time with the following condition met.

    MONITORING CONDITIONS 

    • Electric variable valve timing control: maximum cam retard mode
    • Engine speed: below 5,000 rpm 
    • ECT: above 60°C {140°F} 

Diagnostic support note 
  • This is a continuous monitor (CCM).
  • The check engine light illuminates if the PCM detects the above malfunction condition during the first drive cycle.
  • FREEZE FRAME DATA (Mode 2)/Snapshot data is available.
  • The DTC is stored in the PCM memory.
FAIL-SAFE FUNCTION 
  • Stops activation of the electric variable valve timing driver.
POSSIBLE CAUSE 
  • Electric variable valve timing driver malfunction
    • Electric variable valve timing actuator is stuck in advanced position
  • Electric variable valve timing motor malfunction
  • Electric variable valve timing actuator malfunction
  • PCM malfunction
SYSTEM WIRING DIAGRAM  -
CAUTION:
  • Verify the malfunction symptom according to not only the PID value but also the symptom troubleshooting.
RELATED PIDS

Monitor item (Definition) Unit/Condition Condition/Specification (Reference)
VT_IN_ACT deg;
  • Displays the actual intake valve timing
VT_IN_DES deg;
  • Displays the desired intake valve timing