Diagnostic Procedure
DIAGNOSTIC PROCEDURE DESCRIPTION
| STEP | INSPECTION | RESULTS | ACTION |
|---|---|---|---|
| 1 | DETERMINE IF MALFUNCTION CAUSE IS IMMOBILIZER SYSTEM OR OTHER
|
Yes | Both conditions present:
|
| No | Either or other condition present:
|
||
| 2 | INSPECT PUSH BUTTON START CONNECTOR CONNECTION
|
Yes | Go to the next step. |
| No | Reconnect the push button start securely, then repeat from Step 1. | ||
| 3 | DETERMINE IF MALFUNCTION CAUSE IS INSTRUMENT CLUSTER OR OTHER
|
Yes | Go to the next step. |
| No | Inspect the instrument cluster and related wiring harness. (See INSTRUMENT CLUSTER INSPECTION ). Repair or replace the malfunctioning part according to the inspection results. (See INSTRUMENT CLUSTER REMOVAL/INSTALLATION ). |
||
| 4 | VERIFY IMMOBILIZER SYSTEM DTC
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [IMMOBILIZER SYSTEM] ). |
| No | Go to the next step. | ||
| 5 | VERIFY PCM DTC
|
Yes | Continuous memory DTC is displayed:
Communication error message is displayed:
|
| No | Go to the next step. | ||
| 6 | INSPECT POWER SUPPLY
|
Yes | Go to the next step. |
| No | Inspect the following:
|
||
| 7 | DETERMINE IF MALFUNCTION CAUSE IS STARTER RELAY CONTROL SIGNAL CIRCUIT OR OTHER
|
Yes | Go to Step 17. |
| No | ATX:
MTX:
|
||
| 8 | DETERMINE IF MALFUNCTION CAUSE IS STARTER INTERLOCK SWITCH OR OTHER
|
Yes | Inspect the starter interlock switch. (See STARTER INTERLOCK SWITCH INSPECTION ).
|
| No | Go to the next step. | ||
| 9 | INSPECT STARTER INTERLOCK SWITCH CONNECTOR CONDITION
|
Yes | Repair or replace the connector and/or terminals, then repeat Step 7. |
| No | Go to the next step. | ||
| 10 | INSPECT STARTER INTERLOCK SWITCH GROUND CIRCUIT FOR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible open circuit, then repeat Step 7. | ||
| 11 | INSPECT STARTER RELAY
|
Yes | Replace the starter relay. Repeat Step 7. |
| No | Go to the next step. | ||
| 12 | INSPECT STARTER RELAY CONTROL CIRCUIT FOR SHORT TO GROUND OR OPEN CIRCUIT
|
Yes | Go to the next step. |
| No | Repair or replace the wiring harness for a possible short to ground or open circuit. Repeat Step 7. |
||
| 13 | INSPECT START STOP UNIT CONNECTOR CONDITION
|
Yes | Repair or replace the connector and/or terminals, then repeat Step 7. |
| No | Go to the next step. | ||
| 14 | INSPECT STARTER RELAY CONTROL CIRCUIT FOR SHORT TO GROUND
|
Yes | If the short to ground circuit could be detected in the wiring harness:
If the short to ground circuit could not be detected in the wiring harness:
Repeat Step 7. |
| No | Go to the next step. | ||
| 15 | INSPECT PCM CONNECTOR CONDITION
|
Yes | Repair or replace the connector and/or terminals, then repeat Step 7. |
| No | Go to the next step. | ||
| 16 | INSPECT STARTER RELAY CONTROL CIRCUIT FOR OPEN CIRCUIT
|
Yes | Inspect the start stop unit. (See START STOP UNIT INSPECTION ).
|
| No | Repair or replace the wiring harness for a possible open circuit, then repeat Step 7. | ||
| 17 | INSPECT WIRING HARNESS OF STARTER POWER SUPPLY CIRCUIT
|
Yes | Repair or replace the suspected wiring harness. |
| No | Go to the next step. | ||
| 18 | INSPECT STARTING SYSTEM
|
Yes | Repair or replace the malfunctioning part according to the inspection results. |
| No | Go to the next step. | ||
| 19 | INSPECT IMMOBILIZER SYSTEM RELATED CIRCUIT
|
Yes | Repair or replace the malfunctioning part according to the inspection results. |
| No | Go to the next step. | ||
| 20 | DETERMINE IF MALFUNCTION CAUSE IS BASE ENGINE OR OTHER
|
Yes | Repair or replace the malfunctioning part according to the inspection results. |
| No | Go to the next step. | ||
| 21 | VERIFY PRESENT MALFUNCTION DTC
|
Yes | Go to the applicable DTC inspection. (See DTC TABLE [SKYACTIV-G 2.0] ). |
| No | Go to the next step. | ||
| 22 | Verify the test results.
|
||