Refrigerant Charging: Evacuation

WARNING: This page is about a different car, the 2014 Mazda 6. However, it is still accessible from the selected car via links, so may be relevant.
  1. Open all the valves of the manifold gauge.
    CAUTION:
    • Close the manifold gauge valve immediately after stopping the vacuum pump. If the valve is left open, the vacuum pump oil will back flow into the refrigeration cycle and cause a decrease in the efficiency of the air conditioner.
  2. Start the vacuum pump and let it operate for 15 min. 
    Fig 1: Evacuating Valves Of Manifold Gauge
    G09075740Courtesy of MAZDA MOTORS CORP.
  3. Verify that high- and low-pressure side readings of the manifold gauge are at -101 kPa {-1.03 kgf/cm 2  , -14.6 psi}.  Close each valve of the manifold gauge.
    Fig 2: Checking High And Low Pressure Side Readings Of Manifold Gauge
    G09075741Courtesy of MAZDA MOTORS CORP.