FixVault

Rectifier (Using A Digital Circuit Tester)

  1. Inspect for continuity of the diodes using a digital circuit tester.
    • If not as specified, replace the rectifier.
    TERMINALS CONTINUITY SPECIFICATION

    Negative Positive Continuity
    E P1, P2, P3, P4, P5, P6 No
    B Yes
    P1, P2, P3, P4, P5, P6 E Yes
    B No