FixVault

Check code 6

INSPECTION PROCEDURE (CHECK CODE 6)

Inspection procedure Display Action
Step 1
  1. Press the H button to display check code 6.
  2. Switch the ignition ON (engine off or on).
  3. Verify the screen display.
G09763029
Go to the next step.
G09763030
Refer to the clock inspection and verify the terminal voltage at clock terminal A.
(See CLOCK INSPECTION .)
  • Replace the clock if the voltage is B+.

    (See CLOCK REMOVAL/INSTALLATION .)

  • Inspect the following parts if the voltage is 1.0 V or less.
    • METER1 10 A fuse
    • IG relay
    • Related wiring harness
Step 2
  1. Switch the ignition off (LOCK).
  2. Verify the screen display.
G09763031
Ignition switch ON/OFF signal is normal.
G09763032
Refer to the clock inspection and verify the terminal voltage at clock terminal A.
(See CLOCK INSPECTION .)
  • Replace the clock if the voltage is 1.0 V or more.

    (See CLOCK REMOVAL/INSTALLATION .)

  • Inspect the following parts if the voltage is B+.
    • METER1 10 A fuse
    • IG relay
    • Related wiring harness