DTC P2530-00: Ignition Switch Stuck Off: Notes

DTC P2530:00 Ignition switch stuck off
DETECTION CONDITION 
  • If the IG ON time count of the instrument cluster proceeds 5 s  under the following condition:
    • Ignition switch signal off
FAIL-SAFE FUNCTION  Not applicable
POSSIBLE CAUSE 
  • Start stop unit malfunction
    • Ignition switch signal output stuck off
  • Wiring harness malfunction
    • Short or open signal in ignition switch
    • Ignition switch signal terminal (start stop unit terminal 2S) malfunction
  • Control valve body malfunction
    • Ignition switch signal terminal (start stop unit terminal 2S) pin deformity
SYSTEM WIRING DIAGRAM  Not applicable