Function Inspection Using M-MDS
| STEP | INSPECTION | RESULTS | ACTION |
|---|---|---|---|
| 1 | PURPOSE: VERIFY RELATED REPAIR INFORMATION AVAILABILITY
|
Yes | Perform repair or diagnosis according to the available repair information.
|
| No | Go to the next step. | ||
| 2 | PURPOSE: VERIFY IF POWER SUPPLY IS AFFECTED BY DTC RELATED TO DC-DC CONVERTER (i-ELOOP)
|
Yes | Go to the applicable DTC inspection. (See DTC U3000:49 [I-ELOOP] .) Go to the next step. |
| No | Go to the next step. | ||
| 3 | PURPOSE: VERIFY IF POWER SUPPLY IS AFFECTED BY DTC RELATED TO DC-DC CONVERTER (i-ELOOP)
|
Yes | Go to the applicable DTC inspection. (See DTC P1628:11 [I-ELOOP] .) Go to the next step. |
| No | Go to the next step. | ||
| 4 | PURPOSE: DETERMINE IF MALFUNCTION CAUSED BY DC-DC CONVERTER (i-ELOOP)
|
Yes | Go to the troubleshooting procedure to perform the procedure from Step 1. |
| No | Go to the next step. | ||
| 5 | PURPOSE: DETERMINE LOCATION OF MALFUNCTION OCCURRENCE FROM BLOWN DCDC 200 A FUSE
|
Yes | Go to the troubleshooting procedure to perform the procedure from Step 4. |
| No | Go to the troubleshooting procedure to perform the procedure from Step 6. |