DTC P0713-00: TFT Sensor Circuit High Input: Notes

DTC P0713:00 TFT sensor circuit high input
DETECTION CONDITION 
  • Under the following conditions, the ATF temperature is -40 °C {-40 °F} or less: 
    • Battery voltage is 8 V or more. 
    • The ECU internal temperature is the specified temperature or more.
    • ECU internal temperature sensor related DTC is not recorded.
FAIL-SAFE FUNCTION 
  • Inhibits learning control.
  • Inhibits neutral idle control.
POSSIBLE CAUSE 
  • TFT sensor malfunction
SYSTEM WIRING DIAGRAM  Not applicable