FixVault

DTC U3003-04:Instrument Cluster Configuration Error: Notes

Description Instrument cluster configuration error
Detection condition 
  • Instrument cluster configuration error detected.
Fail-safe 
  • Blind spot monitoring (BSM) system is stopped.
Possible cause 
NOTE:
  • To correctly write the configuration data sent from the instrument cluster to the blind spot monitoring (BSM) control module to the blind spot monitoring (BSM) control module, 30 s or more  need to have elapsed since the ignition was switched ON (engine off or on).
  • Instrument cluster configuration error
  • Blind spot monitoring (BSM) control module malfunction
System wiring diagram  Not applicable