FixVault

DTC P0713-00; TFT Sensor Circuit High Input: Notes

DETECTION CONDITION & POSSIBLE CAUSE

DTC P0713:00 TFT sensor circuit high input
DETECTION CONDITION
  • Under the following conditions, the ATF temperature is -40 °C {-40 °F} or less:
    • Battery voltage is 8 V or more.
    • The ECU internal temperature is the specified temperature or more.
      • ECU internal temperature sensor related DTC is not recorded.
FAIL-SAFE FUNCTION
  • Inhibits learning control.
  • Inhibits neutral idle control.
POSSIBLE CAUSE
  • TFT sensor malfunction
  • Coupler component malfunction
  • TCM malfunction
SYSTEM WIRING DIAGRAM Not applicable