Illumination Light Inspection

  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION .)
  2. Apply battery voltage to TCS OFF switch terminal L, and connect terminal K to ground.
  3. Verify that the LED illuminates.