FixVault

Using The M-MDS

  1. Connect the M-MDS to the DLC-2.
  2. After vehicle identification, select the following from the M-MDS initialization screen.
    1. "DataLogger"
    2. "Modules"
    3. "IC"
  3. Using "SPDMTR", verify that the displayed information is as indicated in the table.
    M-MDS DISPLAY INSTRUMENT CLUSTER DISPLAY
    60 km/h Speedometer needle moves to approx. 58-62 km/h {36-39 mph}.
    120 km/h Speedometer needle moves to approx. 117-123 km/h {72.8-76.4 mph}.
    Off Speedometer needle moves to the bottommost position.
    • If the speedometer does not operate or the indication is not within the allowable range, inspect the DTC inspection for the following control module and the related wiring harnesses.
      • PCM
      • TOM (ATX)
      • DSC HU/CM
    • If the PCM, TOM (ATX), DSC HU/CM, and related wiring harnesses are normal, replace the instrument cluster.