PID/DATA monitor item table
- -: Not applicable
PID/DATA MONITOR DESCRIPTION
| Item (definition) | Unit/Condition | Definition |
|---|---|---|
| A_SCR_C_TMP | °C, °F | Average SCR catalyst temperature |
| C_T_B1S2 | °C, °F | Exhaust gas temperature sensor No. 2 |
| CL_NMHC_MN_CP | - | Catalyst monitoring completed/NMHC catalyst monitoring completed |
| CMP_MNT_ENA | - | Comprehensive component monitoring enabled |
| COMP3_MNT | - | Comprehensive component monitoring completed |
| CONF_URA_TK_LV | - | Configuration for urea tank level |
| CP_IGN_SP | - | Compression ignition monitoring supported |
| CTLY_NMHC_MN | - | Catalyst monitoring/NMHC catalyst monitoring |
| CTRL_MOD_VOL | V | Control module voltage |
| DC_PWM_O_PS_UV | % | Duty cycle of the PWM signal output to the power stage of urea dosing valve |
| DIS_ACT_MIL | km, ft, mi | Distance traveled while check engine light is activated |
| DIS_CLR_DTC | km, ft, mi | Distance Since DTCs cleared |
| DPES_DS_NOX | - | Dew point end signal for downstream NOx sensor |
| DPES_PM | - | Dew point end signal for PM sensor |
| DPES_US_NOX | - | Dew point end signal for upstream NOx sensor |
| DSR_D_AMO | - (mg/s) | Desired dosing amount |
| EG_MF | - (kg/h) | Exhaust gas mass flow |
| EGR_VVT_MCC | - (Undefined/Not Used) | EGR and/or VVT monitor completion condition counts |
| EGR_VVT_MCEC | - (Undefined/Not Used) | EGR and/or VVT monitor conditions encountered counts |
| EGR_VVT_MN_CP | - | EGR and/or VVT system monitoring completed |
| EGR_VVT_MNT | - | EGR and/or VVT system monitoring |
| EGS_MCC | - (Undefined/Not Used) | Gas sensor monitor completion counts |
| EGS_MCEC | - (Undefined/Not Used) | Exhaust gas sensor monitor conditions encountered counts |
| EIAECD1_TT_SUP | - | Total run time with EI-AECD #1 active supported |
| EIAECD1_TT_TM1 | hh:mm:ss | Total run time with EI-AECD #1 Timer 1 active |
| EIAECD1_TT_TM2 | hh:mm:ss | Total run time with EI-AECD #1 Timer 2 active |
| EIAECD2_TT_SUP | - | Total run time with EI-AECD #2 active supported |
| EIAECD2_TT_TM1 | hh:mm:ss | Total run time with EI-AECD #2 Timer 1 active |
| EIAECD2_TT_TM2 | hh:mm:ss | Total run time with EI-AECD #2 Timer 2 active |
| EIAECD3_TT_SUP | - | Total run time with EI-AECD #3 active supported |
| EIAECD3_TT_TM1 | hh:mm:ss | Total run time with EI-AECD #3 Timer 1 active |
| EIAECD3_TT_TM2 | hh:mm:ss | Total run time with EI-AECD #3 Timer 2 active |
| EIAECD4_TT_SUP | - | Total run time with EI-AECD #4 active supported |
| EIAECD4_TT_TM1 | hh:mm:ss | Total run time with EI-AECD #4 Timer 1 active |
| EIAECD4_TT_TM2 | hh:mm:ss | Total run time with EI-AECD #4 Timer 2 active |
| EIAECD5_TT_SUP | - | Total run time with EI-AECD #5 active supported |
| EIAECD5_TT_TM1 | hh:mm:ss | Total run time with EI-AECD #5 Timer 1 active |
| EIAECD5_TT_TM2 | hh:mm:ss | Total run time with EI-AECD #5 Timer 2 active |
| EVAP_SYS_MN | - | Evaporative system monitoring |
| EVAP_SYS_MN_CP | - | Evaporative system monitoring completed |
| FU_SYS_CP | - | Fuel system monitoring completed |
| FU_SYS_ENA | - | Fuel system monitoring enabled |
| FUEL_MCC | - (Undefined/Not Used) | Fuel monitor completion condition counts |
| FUEL_MCEC | - (Undefined/Not Used) | Fuel monitor conditions encountered counts |
| HT_NOX_SRC_MN | - | Heated catalyst monitoring/NOx/SCR after treatment monitoring |
| HTR_TANK | Off/On | Urea tank heater |
| IGN_CYCL_CNT | - (Undefined/Not Used) | Ignition cycle counter |
| INTG_D_MFB | - (g) | Integrated dosing mass feedback |
| IP_C_HT_HCU | - (mA) | Input current of heater from HCU |
| LLMD_SIG2_DNOX | - | Linear lambda signal of 2. downstream Nox sensor from CAN |
| MSF_CP | - | Misfire monitoring completed |
| MSF_ENA | - | Misfire monitoring enabled |
| NMHC_C_MCC | - (Undefined/Not Used) | NMHC catalyst monitor completion counts |
| NMHC_C_MCEC | - (Undefined/Not Used) | NMHC catalyst monitor conditions encountered counts |
| NO_DTM_CCT | - (ppm) | The determined NOx concentration |
| NOX_ADS_MCC | - (Undefined/Not Used) | NOx adsorber monitor completion condition counts |
| NOX_ADS_MCEC | - (Undefined/Not Used) | NOx adsorber monitor conditions encountered counts |
| NOX_C_B1S1 | - (ppm) | The exhaust gas NOx concentration before SCR converter |
| NOX_C_B1S1_SUP | - | The exhaust gas NOx concentration by NOx sensor No. 1 supported |
| NOX_C_B1S2 | - (ppm) | The exhaust gas NOx concentration after SCR converter |
| NOX_C_B1S2_SUP | - | The exhaust gas NOx concentration by NOx sensor No. 2 supported |
| NOX_C_B2S1 | - (ppm) | The exhaust gas NOx concentration before SCR converter |
| NOX_C_B2S1_SUP | - | The exhaust gas NOx concentration by NOx sensor No. 1 supported |
| NOX_C_B2S2 | - (ppm) | The exhaust gas NOx concentration after SCR converter |
| NOX_C_B2S2_SUP | - | The exhaust gas NOx concentration by NOx sensor No. 2 supported |
| NOX_CCT_ATO1 | - (ppm) | NOx Concentration from ATO1 |
| NOX_SCR_C_MCC | - (Undefined/Not Used) | NOx/SCR Catalyst Monitor Completion condition counts |
| NOX_SCR_C_MCEC | - (Undefined/Not Used) | NOx/SCR Catalyst Monitor Conditions encountered counts |
| NOX_SIG_ATO1 | - | NOx signal status from ATO1 |
| NOX_SRC_MN_CP | - | Heated catalyst monitoring completed/NOx/SCR after treatment monitoring completed |
| NOX_ST_SEN_SIG | - | Status of NOx sensor signal |
| O2_CCT_ATO1 | - | Oxygen Concentration from ATO1 |
| O2_SH_PM_F | - | Oxygen sensor heater monitoring/PM filter monitoring |
| O2_SH_PM_F_CP | - | Oxygen sensor heater monitoring completed/PM filter monitoring completed |
| O2_SIG_ST_ATO1 | - | Oxygen signal status from ATO1 |
| O2_SM_EGSM | - | Oxygen sensor monitoring/exhaust gas sensor monitoring |
| O2_SM_EGSM_CP | - | Oxygen sensor monitoring completed/exhaust gas sensor monitoring completed |
| OBD_MCEC | - (Undefined/Not Used) | OBD Monitoring conditions encountered counts |
| OP_ADC | - (mA) | OP of the ADC |
| OP_F_ACT_PS | - (Hz) | Output frequency for activation of the power stage |
| OP_S_FL_H_MM | - (mm, in) | Output signal of the fill level height in mm |
| PMF_MCC PM | - (Undefined/Not Used) | Filter monitor completion condition counts |
| PMF_MCEC | - (Undefined/Not Used) | PM filter monitor conditions encountered counts |
| PMS_A_B1S1 | - | PM sensor active status bank 1 sensor 1 |
| PMS_NO_B1S1 | - (%) | The PM sensor output value |
| PMS_O_B1S1_SUP | - | PM sensor operating status bank 1 sensor 1 supported |
| PMS_O_B2S1_SUP | - | PM sensor operating status bank 2 sensor 1 supported |
| PMS_R_B1S1 | - | PM sensor regen status bank 1 sensor 1 |
| PMS_S_B1S1_SUP | - | PM sensor signal bank 1 sensor 1 supported |
| PMS_S_B2S1_SUP | - | PM sensor signal bank 2 sensor 1 supported |
| RDC_PMP_DC_CM | - | Reductant pump duty cycle - commanded |
| RDCT_INJ_DUCY | % | Reductant injector duty cycle |
| RDCT_LINE_HEAT | - | Reductant line heater |
| RDCT_RVDC_CMD | % | Reductant reverting valve duty cycle - commanded |
| RDCT_TANK_HEAT | - | Reductant tank heater |
| RE_TANK_LV | % | Reagent tank level |
| RE_TANK_LV_SUP | - | Reagent tank level supported |
| REDUCT_INJ_DC | % | Reductant injector duty cycle |
| REV_VALVE | Off/On | Urea reverting valve |
| RLA_UR_PMP_PRE | - (hPa) | DEF pump module pressure |
| RMN_DF_TM_PR_L | -(s) | Remaining defrosting time of the pressure line |
| RMN_DF_TM_TK | -(s) | Remaining defrosting time of the tank |
| RMN_ML_DIRC | - (km mile) | Remaining mileage directly based on reducing agent in tank |
| RMN_TM_SP_DF | -(s) | Remaining time for supply module defrost |
| RRDC_AG_RMN | - (%) | Remaining quantity of reducing agent |
| S_LLMD_V2_DNOX | - | State of lin lambda value of 2.downstream NOx sensor |
| S_STT_HYD_SCR | - | Sub state of hydraulic SCR-system |
| S_UR_TANK_TMP | °C, °F | Sensed urea tank temperature |
| SDARS_BSPR_CP | - | Secondary air system monitoring completed/boost pressure system monitoring completed |
| SDARS_BSTPRE | - | Secondary air system monitoring/boost pressure system monitoring |
| SPDC_URDC | % | Set-point duty cycle from urea dosing controller |
| ST_DF_CHK | - | State of the defrosting check |
| ST_OP_S_PRE_HT | - | Status of output stage pressure heater |
| ST_OP_S_TK_HT | - | Status of output stage tank heater |
| STT_HYD_SCR | - | State of hydraulic SCR-system |
| VOLRDC_AG_RMN | - (l) | Remaining quantity of reducing agent [l] |