PID/DATA Monitor Inspection
NOTE:
- The regulating valve position sensor is integrated in the regulating valve actuator. The regulating valve actuator is integrated in the turbocharger.
- Connect the M-MDS to the DLC-2.
- Switch the ignition ON (engine running).
- Access the PID/DATA monitor item REGVP and simulation item REGV using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST .)
- Verify that the PID/DATA monitor item REGVP changes according to the regulating valve opening angle when the simulation item REGV is set from 0 % to 95 %.
- If not as verified, replace the turbocharger. (See TURBOCHARGER REMOVAL/INSTALLATION .)