FixVault

PID/DATA Monitor Inspection

NOTE:
  • The regulating valve position sensor is integrated in the regulating valve actuator. The regulating valve actuator is integrated in the turbocharger.
  1. Connect the M-MDS to the DLC-2.
  2. Switch the ignition ON (engine running).
  3. Access the PID/DATA monitor item REGVP and simulation item REGV using the M-MDS. (See ON-BOARD DIAGNOSTIC TEST .)
  4. Verify that the PID/DATA monitor item REGVP changes according to the regulating valve opening angle when the simulation item REGV is set from 0 % to 95 %.