FixVault

Blind Spot Monitoring (BSM) Control Module (RH)

Simulation Item Unit/Operation Data Contents Output Part Name Operation Condition
IL_MODE Off/On  
NOTE:
  • Use in conjunction with WRN_IND_R item.
  • Off: Illuminates blind spot monitoring (BSM) OFF indicator light in night mode.
  • On: Illuminates blind spot monitoring (BSM) OFF indicator light in daytime mode.
Blind spot monitoring (BSM) OFF indicator light (Instrument cluster) Ignition switched ON (engine off or on)
RCTA_BUZZER Off/On  
NOTE:
  • Displays in the M-MDS but it does not operate.
WRN_IND_R Off/On
  • Off: Turns off blind spot monitoring (BSM) warning light (RH).
  • On: Illuminates blind spot monitoring (BSM) warning light (RH).
Blind spot monitoring (BSM) warning light (RH) Ignition switched ON (engine off or on)