FixVault

Continuity Inspection

  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION (US) .)
  2. Disconnect the fuel pump unit connector. (See FUEL PUMP UNIT REMOVAL/INSTALLATION .)
  3. Inspect for continuity at the following terminals:
    G13174969Courtesy of MAZDA MOTORS CORP.
    • fuel pump unit terminal A-fuel pump unit terminal D.
    • fuel pump unit terminal D-fuel pump unit terminal E.
    • fuel pump unit terminal E-fuel pump unit terminal A.