Selection Of Procedure For Immobilizer System-Related Parts Programming
- Verify that the ROOM fuse, AT fuse, and SRS2/ESCL fuse are installed.
- Select the applicable programming procedure from the service content of the immobilizer system-related parts.
Programming Procedure Types for Immobilizer System-Related Parts Table
No. Service Programming procedure 1 When programming additional remote transmitter (1) (See NO. 1 ADDITIONAL REMOTE TRANSMITTER PROGRAMMING PROCEDURE (USING THE M-MDS) .) 2 When PCM is replaced (See NO. 2 PROGRAMMING PROCEDURE AFTER PCM REPLACEMENT .) 3 - When start stop unit is replaced
- When PCM and start stop unit are replaced simultaneously
(See NO. 3 PROGRAMMING PROCEDURE WHEN START STOP UNIT IS REPLACED OR WHEN START STOP UNIT AND PCM ARE REPLACED SIMULTANEOUSLY .) 4 - When remote transmitter is replaced
- When remote transmitter is lost
(See NO. 4 PROCEDURE FOR REMOTE TRANSMITTER CLEARING AND NEWLY PROGRAMMING .) (1) Have a remote transmitter that can start the engine. - If servicing is performed after turning off (disabling) the pacemaker radio wave interference prevention function and the power saving function of the remote transmitter, turn on (enable) the functions.