FixVault

LED Illumination Inspection

  1. Disconnect the negative battery terminal. (See NEGATIVE BATTERY TERMINAL DISCONNECTION/CONNECTION (US) .)
  2. Remove the door lock switch. (See DOOR LOCK SWITCH REMOVAL/INSTALLATION (US) .)
  3. Apply battery positive voltage to cluster switch terminal A, and connect terminal B to ground.
    G13178967Courtesy of MAZDA MOTORS CORP.
  4. Verify that the LED is turned on.